APPLICATIONS - Chemical / Pharmaceutical / Cosmetic / Paint
Envochem® COL 20.000 Pre-Treatment of Waste water from production of expanded plastics
Description of the plant:
In an industry area located near to the Persian Gulf next to the Iraqi border plastics are produced (TDI-Plant). Due to these production steps bio-toxic and not bio-degradable waste water arises. Before dumping the waste water into the biological treatment plant, a pre-treatment is necessary. The aim of the pre-treatment is to crack these bio-toxic and not bio-degradable substances and dissipate them to not bio-toxic or bio-degradable compounds. The pre-treatment is the scope of delivery of the company EnviroChemie.
The waste water treatment plant Envochem® COL is designed for an automatic and continuous operation. During the design of the plant the special climatic conditions and the high safety standard of a chemical industry are considered.
The water is treated by the following treatment steps:
- waste water buffering and cooling
- two-step oxidation process with Fenton?s Reagent
- neutralisation
- flocculation
- sedimentation
- sludge dewatering to reduce the sludge volume
- elimination of the exhaust air of the various tanks
Technical data:
| capacity: | Ø 12 m³/h |
| max. 16 m³/h | |
| yield of the organic | |
| components: | > 80 % |
| reaction time in the | |
| reactors: | > 120 min |
| space requirement, tot.: | 17 x 28 m |
| control system: | SPS S7 |
| material of the reactors: | Polypropylen |
| delivery: | Oct 2004 |
Contact
plants.engineering(at)envirochemie.com
Tel: +49 (0) 61 54 / 69 98 - 0