Envochem® Waste water treatment plant for dye and latex waste water
The waste water from both processes is stored separately in large tanks. After the quality of both types of waste water has been homogenized, it is pumped automatically into the treatment reactor. While the agitators are running, ferric chloride, lime milk and flocculant are automatically dosed. The impurities are joined in filterable solids and form a sediment after the agitator has been turned off. After a final pH test, the resulting clear water is discharged.
A chamber filter press compresses the sediment sludge into filter cake.
Performance
| Capacity | 12,5 m3/batch |
| Solids content | 2 - 8 % |
| Temperature of latex waste water | 20 °C |
| Temperature of dye waste water | 90 °C |
Technical data
| Space requirements | 50 m2 over 2 stories |
| Energy consumption | 1 kWh/m3 |
| Material of construction | PP |
| Control | Siemens S7 PLC |
| Filter press volme | 416 l |
| Filter press system | automatic plate transport |
for further information
Enia_Carpets_0107.pdf (175.94 kb)
Contact
plants.engineering(at)envirochemie.com